Steam Boiler Chemical
5, 15, 30, and 55 Gallons of All in One Boiler Chemicals. Choose between an amine or non-amine product.
- Improves boiler reliability and cleanliness.
- All in one product for ease of use.
- Sulfite removes dissolved oxygen.
- Utilizes polymers for excellent control of hardness and iron deposition.
- The polymer is stable over a wide range of temperatures and pressures.
- Feed straight from the container. No mixing required.
- ISO manufactured.
- Product quality insured up to $2,000,000.
- Easy sulfite droplet testing control method.
- Amine product (1197) minimizes corrosion to your condensate pipes.
- ChemWorld 1287 is USDA and FDA approved for use in food regulated facilities.
- ChemWorld 1197 contains DEAE, which is approved per FDA 173.310 for use in the preparation of steam when the steam will contact food or food packaging. FDA limits the amount of DEAE to 15 ppm in the steam, and not for use in milk or milk products. There are no FDA regulations specifying maximum amine concentrations of indirect steam humidification systems. There are regulations regarding air contaminants, such as OSHA 29 CFR 1910.1000, but these do not directly apply to the steam and are difficult to calculate and test for.
How to use:
ChemWorld 1287 and 1197 are all-in-boiler chemicals. They are designed to make boiler chemical feeding and testing easy.
- Download our boiler testing log sheet and use it as a reference.
- Feed the chemical as far back into your steam boiler system (into the feed water tank, DA tank, or feed water line). This will ensure the metal as far back in the system is protected against corrosion.
- Keep a minimum of 20 ppm of sulfite residual (or use ASTM standards) on all active and idle boiler systems to reduce the risk of oxygen corrosion within your boiler. If you have an excess product, it will raise your conductivity levels but will have no adverse effect on your boiler. You are just wasting chemical, water, and thermal energy within the water.
- If your boiler conductivity is too low, you are probably blowdown to much water or grossly overfeeding the chemical. Reduce blowdown and reduce chemical dosage and wait a few days. Allow the water to cycle up again within the boiler. Remember the purpose of your steam boiler system is to reuse water. Target a conductivity of 2,000 to 3,000 umhos (most steam boilers). For mid to large size steam boilers, we always recommend automation with a LakeWood Conductivity Controller. Using a Myron Meter is an easy way to verify the conductivity of your controller and boiler water.
- This chemical will add additional conductivity to your boiler water. Overfeeding will have no adverse effect on the boiler, but it will waste chemicals and you will blowdown excess water. Conductivity is a measurement of dissolved solids, dissolved gases, and suspended solids.
- Add more product as needed based on sulfite residual in your boiler water, but remember to keep your conductivity in range or your sulfite reading will be irrelevant. Use a Sulfite Test Kit to verify your residual.
- This product needs to be added daily, bi-weekly, or weekly depending on how your systems operate. In theory, the more frequently you add it, the less of the product you will use.
- The purpose of the chemical is to prevent corrosion and scale prevention. As long as you have any sulfite in the boiler water, it means you have no dissolved oxygen in the boiler water.
- If you have any other questions, please email us at tech@chemworld.com. Remember to keep it simple. This is an easy boiler chemical to use as long as you get it into the system, you maintain proper conductivity levels within the boiler, you have a good operating softener, and you periodically check that sulfite is in the boiler. Do not over complicate it.
For new steam boiler startups, consider purchasing our Steam Boiler Startup Kit.Looking for boiler chemical treatment that can be used in an organic certified food facility. Do you have one? We have not heard of an organic boiler chemicals. All we have in FDA approved chemicals.
Does the all in one boiler treatment 1197 contain benzene? No our Chemworld 1197 does not contain benzene.
What is the recommended feedrate for the Chemworld 1287? The Feedrates are 650 to 2000 ppm in the boiler.