Taylor K-9065
ChemWorld is a distributor of Taylor Technologies Test Kits and Reagents. Order directly online and save today.DROP TEST QUATERNARY AMMONIUM COMPOUND (QAC) (1 drop = 1.25 ppm) > & POLYQUAT (1 drop = 0.5 ppm)
COMPONENTS: 1 x 5385 Instruction 1 x 9012 Pipet, Calibrated 0.5 & 1.0 mL, plastic w/brown cap 1 x 9198BR Sample Tube, Graduated, 25 mL, plastic w/cap and brown dot 1 x R-0638BR-C Phenolphthalein Indicator (brown cap), 2 oz, DB 1 x R-0736BR-C Sulfuric Acid .6N (brown cap), 2 oz, DB 1 x R-0881-C Toluidine Blue O Indicator, 2 oz, DB 1 x R-0950-C Complexing Reagent, 2 oz 1 x R-0951-C QAC Titrating Solution, 2 oz, DB
Quaternary Ammonium Compound (QAC) Test
For 1 drop = 1.25 ppm QAC
NOTE: Run a blank using water containing no QAC. Record drops of R-0951 QAC Titrating Solution used.
1. Rinse and fill 25 mL sample tube (#9198BR) to 25 mL mark with water to be tested.
2. Using a 1.0 mL pipet (#9012), add 1.0 mL R-0950 Complexing Reagent. NOTE: If sample water contains a hardness concentration above 500 ppm, add 2.0 mL (2 x 1.0 mL) R-0950 Complexing Reagent.
3. Add 1 drop R-0638BR Phenolphthalein Indicator. Swirl to mix. If colorless, proceed to step
4. If pink, add R-0736BR Sulfuric Acid .6N dropwise, swirling after each drop, until color changes from pink to colorless.
4. Add 3 drops R-0881 Toluidine Blue O Indicator. Swirl to mix. If QAC is present, sample should turn light blue.
5. Add R-0951 QAC Titrating Solution dropwise, swirling and counting after each drop, until color changes from light blue to violet-pink. Always hold bottle in vertical position. NOTE: Further addition of R-0951 QAC Titrating Solution should produce no color change.
6. Subtract drops of R-0951 QAC Titrating Solution used in blank from drops used in sample (step 5). Multiply by 1.25. Record as parts per million (ppm) QAC as n-alkyl(50% C14, 40% C12, 10% C16) dimethylbenzylammonium chloride.
NOTE: Equivalences for quaternary ammonium compounds other than those listed must be determined by titration with a known standard. Polyquat Test For 1 drop = 0.5 ppm NOTE: Run a blank using water containing no polyquat. Record drops of R-0951 QAC Titrating Solution used.
1. Rinse and fill 25 mL sample tube (#9198BR) to 25 mL mark with water to be tested.
2. Using a 1.0 mL pipet (#9012), add 1.0 mL R-0950 Complexing Reagent. NOTE: If sample water contains hardness concentration above 500 ppm, add 2.0 mL (2 x 1.0 mL) R-0950 Complexing Reagent.
3. Add 1 drop R-0638BR Phenolphthalein Indicator. Swirl to mix. If colorless, proceed to step 4. If pink, add R-0736BR Sulfuric Acid .6N dropwise, swirling after each drop, until color changes from pink to colorless.
4. Add 3 drops R-0881 Toluidine Blue O Indicator. Swirl to mix. If polyquat is present, sample should turn light blue.
5. Add R-0951 QAC Titrating Solution dropwise, swirling and counting after each drop, until color changes from light blue to violet-pink. Always hold bottle in vertical position.
NOTE: Further addition of R-0951 QAC Titrating Solution should produce no color change.
6. Subtract drops of R-0951 QAC Titrating Solution used in blank from drops used in sample (step 5). Multiply by 0.5. Record as parts per million (ppm) polyquat as poly[(oxyethylenedimethyliminio)ethylene (dimethyliminio)ethylenedichloride].
NOTE: Equivalences for polyquats other than those listed must be determined by titration with a known standard.
One gallon containers of Boiler Antifreeze are Stocked & Shipped daily from Atlanta, Georgia; Detroit, Michigan; and Salt Lake City, Utah.
Notes:
Daily shipping cut off time is generally 1 pm, based on the local time zone for same day shipping. If you need this product to ship today, please indicate so in the notes section upon check out. We will email mail you ASAP if we can meet your demands.
Figure 1- Fedex Residential and Ground
Transit Time Map
Notes:
- We only ship via FedEx ground. No UPS or USPS.
- We can not ship to PO boxes.
- This map illustrates service schedules in business days as of Dec 2016 for FedEx Ground shipments.
- ChemWorld is not responsible for delays due to weather or Fedex transit issues. Please take this into account when ordering.
- Orders must be received by noon.
- We only ship FedEx expedite shipments. No UPS or USPS.
- To calculate your costs, log into your FedEx Account. Origin zip code is 30144, 48180, or 84119.
- Order must be placed by noon.
- Order as normal through the website.
- If you have a FedEx Account number, enter it in the notes section during ordering with your exact shipping requirements (Next Day 8:30, Next Day 10:30, Next Day 20:00, Fedex 2 AM, or FedEx Express Saver). You are done. We will email you ASAP.
- If you do NOT have a FedEx Account number, we offer overnight delivery for this product. The cost is $60 for Next Day 10:30 AM per 1-gallon box. Enter your order as normal and enter your 3 or 4 digit security code in the notes section with your shipping requirements. You are done. We will email you ASAP.
If it is later then noon, email us at quotes@chemworld.com with your request. We will contact you ASAP. You can also call in the order at 800-658-7716 and reference exactly what you need. We will contact you.
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device