DROP TEST HARDNESS - TOTAL

COMPONENTS: 1 x 5067B Instruction 1 x 9198B Sample Tube, Graduated, 25 mL, plastic w/cap and blue dot 1 x R-0619B-C Hardness Buffer (blue cap), 2 oz, DB 1 x R-0620B-I Hardness Indicator Powder (blue cap), 10 g 1 x R-0683-C Hardness Reagent, 2 oz, DB.

Hardness-total (Drop Test)

1. Rinse and fill 25 mL sample tube (#9198B) to 25 mL mark with water to be tested.
2. Add 5 drops R-0619B Hardness Buffer. Swirl to mix.
3. Add 1 dipper R-0620B Hardness Indicator Powder. Swirl until dissolved. If hardness is present, sample will turn red.
4. Add R-0683 Hardness Reagent dropwise, swirling and counting after each drop, until color changes from red to blue. Always hold bottle in vertical position.
5. Multiply drops of R-0683 Hardness Reagent by 10. Record as parts per million (ppm) total hardness as calcium carbonate.


DROP TEST ALKALINITY - PM/PT

COMPONENTS: 1 x 5067G Instruction 1 x 9198G Sample Tube, Graduated, 25 mL, plastic w/cap and green dot 1 x R-0637-C Methyl Orange Indicator, 2 oz, DB 1 x R-0638G-A Phenolphthalein Indicator (green cap), .75 oz, DB 1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB 1 x R-0687G-C Sulfuric Acid .12N (green cap), 2 oz, DB.

Alkalinity-P/M (Drop Test)

1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL mark with water to be tested.
2. Add 3 drops R-0638G Phenolphthalein Indicator. Swirl to mix. Sample will turn pink if P alkalinity is present--proceed to Step 3. If no pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N dropwise, swirling and counting after each drop, until color changes from pink to colorless. Record drops as P reading. Always hold bottle in vertical position.
4. Add 5 drops R-0637 Methyl Orange Indicator. Swirl to mix. Sample should turn yellow.
5. Continue adding R-0687G Sulfuric Acid .12N dropwise, swirling and counting after each drop, until color just changes from yellow to orange (salmon pink). Record total drops (Steps 3 and 5) as M reading. Always hold bottle in vertical position.
6. Multiply P reading by 10. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply M reading by 10. Record as ppm M alkalinity as calcium carbonate.

Alkalinity-P/T (Drop Test)

1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL mark with water to be tested.
2. Add 3 drops R-0638G Phenolphthalein Indicator. Swirl to mix. Sample will turn pink if P alkalinity is present--proceed to Step 3. If no pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N dropwise, swirling and counting after each drop, until color just changes from pink to colorless. Record drops as P reading. Always hold bottle in vertical position.
4. Add 5 drops R-0645 Total Alkalinity Indicator. Swirl to mix. Sample should turn green.
5. Continue adding R-0687G Sulfuric Acid .12N dropwise, swirling and counting after each drop, until color changes from green to red. Record total drops (Steps 3 and 5) as T reading. Always hold bottle in vertical position. 6. Multiply P reading by 10. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply T reading by 10. Record as ppm T alkalinity as calcium carbonate.


DROP TEST ORTHOPHOSPHATE (HIGH)

COMPONENTS: Orthophosphate (high) 1 x 5067OP Instruction 2 x 2269 Caps, Dispenser, 18 mm, plastic 1 x 4027 Funnel, 58 mm, plastic 1 x 6003 Brush, Test Tube 1 x 6009 Filter Paper, #610, 9.0 cm, 100/box 1 x 9021 Test Tube, Mixing, Calibrated 5, 10, 14, 15, 17.5 mL, glass w/stopper 1 x 9025 Comparator, 2 Standard, Orthophosphate (high), 30 & 60 ppm 2 x R-0601-C Molybdate Reagent, 2 oz 1 x R-0602P-I Stannous Chloride Powder, 10 g.

Orthophosphate (high) (Color Comparison)

1. Filter water to be tested to clarify.

2. Rinse and fill mixing test tube (#9021) to 5 mL mark with filtered sample.
3. Cap R-0601 Molybdate Reagent with 18 mm dispenser cap (#2269). Add R-0601 Molybdate Reagent to 15 mL mark. Stopper and mix. Remove stopper.
4. Add 2 level dippers R-0602P Stannous Chloride Powder. Stopper and mix.
5. Wipe dry and place in hole of comparator. WAIT 1 MINUTE. Read before 10 minutes. 6. Match color in mixing test tube with a color standard. Record as parts per million (ppm) orthophosphate.


DROP TEST SULFITE, SODIUM

COMPONENTS: Sulfite, Sodium 1 x 5067W Instruction 1 x 9198W Sample Tube, Graduated, 25 mL, plastic w/cap and white dot 1 x R-0638W-C Phenolphthalein Indicator (white cap), 2 oz, DB 1 x R-0699-C Iodide Iodate Reagent, 2 oz, DB 1 x R-0725-I Acid Starch Indicator Powder, 10 g. Sulfite, Sodium (Drop Test)

1. Collect water to be tested in a clean, preferably large-mouthed, bottle to overflowing. Immediately cap and cool to room temperature.
2. Rinse and fill 25 mL sample tube (#9198W) to 25 mL mark with cooled (room temperature) water to be tested.
3. Add 1 drop R-0638W Phenolphthalein Indicator. Swirl to mix. Sample should turn red.
4. Add R-0725 Acid Starch Indicator Powder, a dipper at a time, swirling after each dipper, until color changes from red to colorless. Add 2 more dippers. Swirl until dissolved.
5. Add R-0699 Iodide Iodate Reagent dropwise, swirling and counting after each drop, until color changes from colorless to a faint but permanent blue. Always hold bottle in vertical position.
6. Multiply drops of R-0699 Iodide Iodate Reagent by 10. Record as parts per million (ppm) sodium sulfite.
One gallon containers of Boiler Antifreeze are Stocked & Shipped daily from Atlanta, Georgia; Detroit, Michigan; and Salt Lake City, Utah.

Daily shipping cut off time is generally 1 pm, based on the local time zone for same day shipping. If you need this product to ship today, please indicate so in the notes section upon check out. We will email mail you ASAP if we can meet your demands.

Figure 1- Fedex Residential and Ground
Transit Time Map




Notes:
  • We only ship via FedEx ground. No UPS or USPS.
  • We can not ship to PO boxes.
  • This map illustrates service schedules in business days as of Dec 2016 for FedEx Ground shipments.
  • ChemWorld is not responsible for delays due to weather or Fedex transit issues. Please take this into account when ordering.
Overnight / Expedite Shipping:
  • Orders must be received by noon.
  • We only ship FedEx expedite shipments. No UPS or USPS.
  • To calculate your costs, log into your FedEx Account. Origin zip code is 30144, 48180, or 84119.
Directions for Overnight Shipping:
  • Order must be placed by noon.
  • Order as normal through the website.
  • If you have a FedEx Account number, enter it in the notes section during ordering with your exact shipping requirements (Next Day 8:30, Next Day 10:30, Next Day 20:00, Fedex 2 AM, or FedEx Express Saver). You are done. We will email you ASAP.
  • If you do NOT have a FedEx Account number, we offer overnight delivery for this product. The cost is $60 for Next Day 10:30 AM per 1-gallon box. Enter your order as normal and enter your 3 or 4 digit security code in the notes section with your shipping requirements. You are done. We will email you ASAP.

If it is later then noon, email us at quotes@chemworld.com with your request. We will contact you ASAP. You can also call in the order at 800-658-7716 and reference exactly what you need. We will contact you.