Taylor K-1533PM
ChemWorld is a distributor of Taylor Technologies Test Kits and Reagents. Order directly online and save today.DROP TEST P/M OR P/T ALKALINITY (1 drop = 10 or 50 ppm)
COMPONENTS: 1 x 5084 Instruction 1 x 9198G Sample Tube, Graduated, 25 mL, plastic w/cap and green dot *1 x R-0637-C Methyl Orange Indicator, 2 oz, DB 1 x R-0638G-C Phenolphthalein Indicator (green cap), 2 oz, DB *1 x R-0645-C Total Alkalinity Indicator, 2 oz, DB 1 x R-0687G-C Sulfuric Acid .12N (green cap), 2 oz, DB 1 x R-0736G-C Sulfuric Acid .6N (green cap), 2 oz, DB
*Kit contains only one of these indicators.
P/M Alkalinity
NOTE:
For 1 drop = 10 ppm, use R-0687G Sulfuric Acid .12N.
For 1 drop = 50 ppm, use R-0736G Sulfuric Acid .6N.
1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL mark with water to be tested. NOTE: For results in grains per gallon (gpg), fill to 14.6 mL mark.
2. Add 3 drops R-0638G Phenolphthalein Indicator. Swirl to mix. Sample will turn pink if P alkalinity is present--proceed to Step 3. If no pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N or R-0736G Sulfuric Acid .6N dropwise, swirling and counting after each drop, until color just changes from pink to colorless. Record drops as P reading. Always hold bottle in vertical position.
4. Add 3 drops R-0637 Methyl Orange Indicator. Swirl to mix. Sample should turn yellow.
5. Continue adding R-0687G Sulfuric Acid .12N or R-0736G Sulfuric Acid .6N dropwise, swirling and counting after each drop, until color just changes from yellow to orange (salmon pink). Record total drops (Steps 3 and 5) as M reading. Always hold bottle in vertical position.
6. If R-0687G Sulfuric Acid .12N was used, multiply P reading by 10. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply M reading by 10. Record as ppm M alkalinity as calcium carbonate. For 14.6 mL sample, record P reading as grains per gallon (gpg) P alkalinity as calcium carbonate. Record M reading as gpg M alkalinity as calcium carbonate. If R-0736G Sulfuric Acid .6N was used, multiply P reading by 50. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply M reading by 50. Record as ppm M alkalinity as calcium carbonate. For 14.6 mL sample, multiply P reading by 5. Record as grains per gallon (gpg) P alkalinity as calcium carbonate. Multiply M reading by 5. Record as gpg M alkalinity as calcium carbonate. P/T Alkalinity
NOTE:
For 1 drop = 10 ppm, use R-0687G Sulfuric Acid .12N.
For 1 drop = 50 ppm, use R-0736G Sulfuric Acid .6N.
1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL mark with water to be tested. NOTE: For results in grains per gallon (gpg), fill to 14.6 mL mark.
2. Add 3 drops R-0638G Phenolphthalein Indicator. Swirl to mix. Sample will turn pink if P alkalinity is present--proceed to Step 3. If no pink color, go to Step 4.
3. If pink, add R-0687G Sulfuric Acid .12N or R-0736G Sulfuric Acid .6N dropwise, swirling and counting after each drop, until color just changes from pink to colorless. Record drops as P reading. Always hold bottle in vertical position.
4. Add 5 drops R-0645 Total Alkalinity Indicator. Swirl to mix. Sample should turn green.
5. Continue adding R-0687G Sulfuric Acid .12N or R-0736G Sulfuric Acid .6N dropwise, swirling and counting after each drop, until color changes from green to red. Record total drops (Steps 3 and 5) as T reading. Always hold bottle in vertical position.
6. If R-0687G Sulfuric Acid .12N was used, multiply P reading by 10. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply T reading by 10. Record as ppm T alkalinity as calcium carbonate. For 14.6 mL sample, record P reading as grains per gallon (gpg) P alkalinity as calcium carbonate. Record T reading as gpg T alkalinity as calcium carbonate. If R-0736G Sulfuric Acid .6N was used, multiply P reading by 50. Record as parts per million (ppm) P alkalinity as calcium carbonate. Multiply T reading by 50. Record as ppm T alkalinity as calcium carbonate. For 14.6 mL sample, multiply P reading by 5. Record as grains per gallon (gpg) P alkalinity as calcium carbonate. Multiply T reading by 5. Record as gpg T alkalinity as calcium carbonate.
One gallon containers of Boiler Antifreeze are Stocked & Shipped daily from Atlanta, Georgia; Detroit, Michigan; and Salt Lake City, Utah.
Notes:
Daily shipping cut off time is generally 1 pm, based on the local time zone for same day shipping. If you need this product to ship today, please indicate so in the notes section upon check out. We will email mail you ASAP if we can meet your demands.
Figure 1- Fedex Residential and Ground
Transit Time Map
Notes:
- We only ship via FedEx ground. No UPS or USPS.
- We can not ship to PO boxes.
- This map illustrates service schedules in business days as of Dec 2016 for FedEx Ground shipments.
- ChemWorld is not responsible for delays due to weather or Fedex transit issues. Please take this into account when ordering.
- Orders must be received by noon.
- We only ship FedEx expedite shipments. No UPS or USPS.
- To calculate your costs, log into your FedEx Account. Origin zip code is 30144, 48180, or 84119.
- Order must be placed by noon.
- Order as normal through the website.
- If you have a FedEx Account number, enter it in the notes section during ordering with your exact shipping requirements (Next Day 8:30, Next Day 10:30, Next Day 20:00, Fedex 2 AM, or FedEx Express Saver). You are done. We will email you ASAP.
- If you do NOT have a FedEx Account number, we offer overnight delivery for this product. The cost is $60 for Next Day 10:30 AM per 1-gallon box. Enter your order as normal and enter your 3 or 4 digit security code in the notes section with your shipping requirements. You are done. We will email you ASAP.
If it is later then noon, email us at quotes@chemworld.com with your request. We will contact you ASAP. You can also call in the order at 800-658-7716 and reference exactly what you need. We will contact you.