Taylor K-1692

Taylor K-1692

Our Price: $538.38

Availability: Usually Ships in 24 Hours

Product Code: k-1692

Taylor K-1692

ChemWorld is a distributor of Taylor Technologies Test Kits and Reagents. Order directly online and save today.

TURBIDIMETRIC TEST POLYMER (0-10 PPM)

REAGENTS: R-0830 Polymer Reagent 1 R-0831 Polymer Reagent 2 APPARATUS: 2 x 4030 Pipets, Calibrated 0.5 & 1.0 mL, plastic 1 x 5190 Instruction 1 x 6249 Filter Holder, 25 mm, Millipore 1 x 6257 Filter Discs, 2.5 um, 100/box 1 x 6260 Syringe, 30 mL, plastic 1 x 9198 Sample Tube, Graduated, 25 mL, plastic w/cap.

NOTE: It is important to adhere to the timed waiting periods for accurate results.

NOTE: Positive interferences: Cationic surfactants,and Polyphosphates at all levels. Negative interferences: Alkalinity >300 ppm CaCO3; Anionic surfactants at all levels; Azoles >10 ppm; Fluoride >20 ppm; Glutaraldehyde >50 ppm; Hardness >700 ppm; Iron >10 ppm; Molybdenum >10 ppm; Orthophosphate >100 ppm; Phosphonate (ATMP, HEDP, PBTC) >100 ppm; Silica >100 ppm; Sulfate >1000 ppm; TDS >1500 ppm; Zinc >100 ppm.

1. Draw water to be tested into 30 mL syringe (#6260) to 30 mL mark.
2. Remove cap from bottom of a clean, dry sample tube (#9198).
3. Following the instructions below, filter water into sample tube. Do not empty or disassemble syringe filtration system. Retain for later use, if needed. a. Open filter holder (#6249) and place 1 filter disc (#6257) into filter holder. Screw filter holder together. b. Screw filter holder onto syringe being careful not to push on plunger. c. Slowly depress plunger to filter water into sample tube to 25 mL mark.
4. Using a 1.0 mL pipet (#4030) add 2.5 mL of R-0830 Polymer Reagent 1. Swirl to mix.
5. With a second 1.0 mL pipet (#4030) add 2.5 mL of R-0831 Polymer Reagent 2. Swirl to mix.
6. Place sample tube on center dot of turbidity standards and wait 5 minutes.
7. At exactly 5 minutes match the turbidity in the test sample with closest dot on chart by looking down through solution. (Arrows denote interpolated values between standards.) Record results as parts per million (ppm) polyacrylic acid. NOTE: Clean and thoroughly rinse all apparatus (sample tubes, syringe, filter holder, test cell, and pipets) with distilled, deionized, or tap water between tests. Pipets should be disassembled and all parts thoroughly rinsed. Syringe and filter holder should be cleaned as follows: Unscrew filter holder from syringe. Open filter holder and discard filter disc. Draw up deionized, distilled, or tap water in syringe. Screw filter holder together and replace on syringe. Depress plunger to clean and rinse. Repeat as necessary.

SYRINGE FILTRATION SYSTEM COMPONENTS: 1 x 5860 Instruction *1 x 6247 Syringe, 60 mL, plastic 1 x 6249 Filter Holder, 25 mm, Millipore *1 x 6260 Syringe, 30 mL, plastic Also required but not included: filter discs *Kit may only contain one of these.

NOTE:
Taylor offers one pore size in a paper filter disc: 2.5 um filter disc (#6257); and two pore sizes in MCE membrane filter discs: 5 um filter disc (#6248) and .45 um filter disc (#6261). The syringe filtration system removes colloidal color and turbidity, which would interfere when using the Midget(TM) comparator system. This system is offered separately and in other Taylor test kits.

1. Open filter holder (#6249) and place 1 filter disc (#6248, #6257, or #6261) into filter holder. Screw filter holder together and set aside.
2. Completely depress syringe plunger (#6247 or #6260). Draw up water to be filtered by pulling plunger to the highest mL mark.
3. Screw filter holder onto syringe being careful not to push on plunger.
4. Slowly depress plunger to filter water into clean collection vessel. Use filtered water as sample in test.
5. Unscrew filter holder from syringe. Open filter holder and discard filter disc. Draw up deionized, distilled, or tap water into syringe. Screw filter holder together and replace on syringe. Depress plunger to clean and rinse. Repeat as necessary.

COOLING SYSTEM & POLYMER TESTS

COMPONENTS (not Bill of Materials): Alkalinity-total 1 x 9198G Sample Tube, Graduated, 25 mL, plastic w/cap 1 x R-0645 Total Alkalinity Indicator, DB 1 x R-0687G Sulfuric Acid .12N, DB Chloride 1 x 9198O Sample Tube, Graduated, 25 mL, plastic w/cap 1 x R-0630 Chromate Indicator, DB 1 x R-0638O Phenolphthalein Indicator, DB *1 x R-0686P Sulfuric Acid N, DB 1 x R-0706 Silver Nitrate Reagent, DB Hardness-calcium 1 x 9198B Sample Tube, Graduated, 25 mL, plastic w/cap 1 x R-0011L Calcium Indicator Liquid, DB 1 x R-0653-2 Calcium Buffer, DB 1 x R-0683 Hardness Reagent, DB Nitrite-sodium 1 x 9198R Sample Tube, Graduated, 25 mL, plastic w/cap 1 x R-0819 Ferroin Indicator, DB 1 x R-0820 CAN Solution, DB Phosphonate 1 x 9198P Sample Tube, Graduated, 25 mL, plastic w/cap 1 x 9315 Test Paper, pH, 1.8-3.8 *1 x R-0686P Sulfuric Acid N, DB 1 x R-0697 Thiosulfate N/10, DB 1 x R-0802P XO Indicator Powder 1 x R-0803 Phosphonate Titrating Solution 1 x R-0805 Fluoride Masking Agent, DB Polymer 1 x 5190 Instruction and Color Chart 1 x 9198 Sample Tube, Graduated, 25 mL, plastic w/cap 1 x R-0830 Polymer Reagent #1 1 x R-0831 Polymer Reagent #2 Misc. 1 x 5860 Instruction - Syringe Filtration System 1 x 5871 Instruction *Kit contains one.

Alkalinity-total

1. Rinse and fill 25 mL sample tube (#9198G) to 25 mL mark with water to be tested.
2. Add 3 drops R-0645 Total Alkalinity Indicator. Swirl to mix. Sample should turn green.
3. Add R-0687G Sulfuric Acid .12N dropwise, swirling and counting after each drop, until color changes from green to red.
4. Multiply drops of R-0687G Sulfuric Acid .12N by 10. Record as parts per million (ppm) total alkalinity as calcium carbonate.

Chloride

NOTE: When sulfite content of sample water to be tested exceeds 10 ppm, the sulfite should be oxidized to prevent interference in test. A 25 mL water sample is first adjusted to the appropriate pH, then 1 mL (or 24 drops) of R-0649 3% Hydrogen Peroxide Solution (sold separately) is added and thoroughly mixed. Continue with the rest of the procedure.

1. Rinse and fill 25 mL sample tube (#9198O) to 25 mL mark with water to be tested.
2. Add 2 drops R-0638O Phenolphthalein Indicator. Swirl to mix. If sample turns red, add R-0686P Sulfuric Acid N dropwise, swirling after each drop, until color changes from red to colorless.
3. Add 5 drops R-0630 Chromate Indicator. Swirl to mix. Sample should turn yellow.
4. Add R-0706 Silver Nitrate Reagent dropwise, swirling and counting after each drop, until color changes from yellow to a milky salmon (brick) red. Always hold bottle in vertical position. NOTE: Do not add enough R-0706 Silver Nitrate Reagent to give a brown color. First change from yellow to a milky salmon (brick) red is the endpoint.
5. Multiply drops of R-0706 Silver Nitrate Reagent by 10. Record as parts per million (ppm) chloride.

Hardness-calcium

1. Rinse and fill 25 mL sample tube (#9198B) to 25 mL mark with water to be tested.
2. Add 10 drops R-0653-2 Calcium Buffer. Swirl to mix.
3. Add 5 drops R-0011L Calcium Indicator Liquid. Swirl to mix. If hardness is present, sample will turn red.
4. Add R-0683 Hardness Reagent dropwise, swirling and counting after each drop, until color changes from red to blue. Always hold bottle in vertical position.
5. Multiply drops of R-0683 Hardness Reagent by 10. Record as parts per million (ppm) calcium hardness as calcium carbonate.

Nitrite-sodium

1. Rinse and fill 25 mL sample tube (#9198R) to 5 mL mark with cooled (room temperature) water to be tested.
2. Add 4 drops R-0819 Ferroin Indicator. Swirl to mix. Sample should turn red (orange).
3. Add R-0820 CAN Solution dropwise, swirling and counting after each drop, until color changes from red (orange) to blue. Always hold bottle in vertical position.
4. Multiply drops of R-0820 CAN Solution by 40. Record as parts per million (ppm) sodium nitrite.

Phosphonate

NOTE: Run a blank using tap water. Normal blank requires about 2 drops of R-0803 Phosphonate Titrating Solution to reach endpoint.

1. Rinse and fill 25 mL sample tube (#9198P) to 25 mL mark with water to be tested.
2. Add: 1 drop R-0697 Thiosulfate N/10 10 drops R-0805 Fluoride Masking Agent 1 level dipper R-0802P XO Indicator Powder Swirl to mix.
3. Adjust pH between 2.6 and 3.0: Add 1 drop R-0686P Sulfuric Acid N. Swirl to mix. Dip test paper (#9315) into sample in direction of arrow, for 3 seconds, with all color zones immersed. Match indicator zone (the unnumbered square located between 2.7 and 3.0 color standards) with color scale. Read printed pH value. If necessary, continue adding R-0686 Sulfuric Acid N dropwise, swirling and checking pH with a new test paper after each drop, until a pH between 2.6 and 3.0 is obtained. Sample should be yellow.
4. Add R-0803 Phosphonate Titrating Solution dropwise, swirling and counting after each drop, until color changes from yellow to purple-pink. Always hold bottle in vertical position.
5. Subtract drops of R-0803 Phosphonate Titrating Solution in blank from drops in sample (Step 4). Multiply by appropriate conversion factor (see CONVERSION FACTORS). Record as parts per million (ppm) phosphonate.
One gallon containers of Boiler Antifreeze are Stocked & Shipped daily from Atlanta, Georgia; Detroit, Michigan; and Salt Lake City, Utah.

Daily shipping cut off time is generally 1 pm, based on the local time zone for same day shipping. If you need this product to ship today, please indicate so in the notes section upon check out. We will email mail you ASAP if we can meet your demands.

Figure 1- Fedex Residential and Ground
Transit Time Map




Notes:
  • We only ship via FedEx ground. No UPS or USPS.
  • We can not ship to PO boxes.
  • This map illustrates service schedules in business days as of Dec 2016 for FedEx Ground shipments.
  • ChemWorld is not responsible for delays due to weather or Fedex transit issues. Please take this into account when ordering.
Overnight / Expedite Shipping:
  • Orders must be received by noon.
  • We only ship FedEx expedite shipments. No UPS or USPS.
  • To calculate your costs, log into your FedEx Account. Origin zip code is 30144, 48180, or 84119.
Directions for Overnight Shipping:
  • Order must be placed by noon.
  • Order as normal through the website.
  • If you have a FedEx Account number, enter it in the notes section during ordering with your exact shipping requirements (Next Day 8:30, Next Day 10:30, Next Day 20:00, Fedex 2 AM, or FedEx Express Saver). You are done. We will email you ASAP.
  • If you do NOT have a FedEx Account number, we offer overnight delivery for this product. The cost is $60 for Next Day 10:30 AM per 1-gallon box. Enter your order as normal and enter your 3 or 4 digit security code in the notes section with your shipping requirements. You are done. We will email you ASAP.

If it is later then noon, email us at quotes@chemworld.com with your request. We will contact you ASAP. You can also call in the order at 800-658-7716 and reference exactly what you need. We will contact you.